Pluggable Terminal Block
Home

Blog

Blog

  • Common problems and solutions of wiring terminal block
    Aug 21, 2024
    There are three common problems with wiring terminals in use:   1. Poor contact The metal conductor inside the terminal block is the core component of the terminal, which transmits voltage, current or signal from external wires or cables to the corresponding contact of the connector that matches it. Therefore, the contact piece must have excellent structure, stable and reliable contact retention force, and good conductivity. Due to the unreasonable design of the contact structure, incorrect material selection, unstable mold, processing size deviation, rough surface, unreasonable surface treatment processes such as heat treatment and electroplating, improper assembly, poor storage and use environment, and improper operation and use, poor contact can be caused at the contact and mating parts of the contact.   2. Poor insulation The function of an insulator is to keep the contacts in the correct position and to insulate them from each other, as well as from the housing. Therefore, insulation components must have excellent electrical, mechanical, and process forming properties. Especially with the widespread use of high-density and miniaturized terminal blocks, the effective wall thickness of insulators is becoming thinner and thinner. This puts forward stricter requirements for insulation materials, injection mold accuracy, and molding processes. Due to the presence of metal residues, surface dust, solder flux, and other contaminants on or inside the insulator, as well as the fusion of organic material precipitates and harmful gas adsorption films with surface water films to form ionic conductive channels, moisture absorption, mold growth, insulation material aging, etc., all of these can cause insulation defects such as short circuits, leakage, breakdown, and low insulation resistance.   3. Poor fixation Insulators not only serve as insulation, but also provide precise neutralization protection for protruding contacts. They also have the functions of installation positioning, locking and fixing on equipment. Poor fixation can cause momentary power outage due to poor contact reliability in mild cases, and product disassembly in severe cases. Disassembly refers to the abnormal separation between plugs and sockets, as well as between pins and sockets, caused by structural unreliability due to material, design, process, and other reasons when the wiring terminal is in the plugged in state. This will result in serious consequences such as interruption of power transmission and signal control in the control system. Due to unreliable design, incorrect material selection, improper selection of molding processes, poor quality of heat treatment, molds, assembly, welding and other processes, and inadequate assembly, poor fixation can be caused. The main solutions are: 1. Prevent poor contact 1) Continuity detection At present, some key models of products should increase 100% point by point conductivity testing.   2) Instant break detection Some wiring terminals are used in dynamic vibration environments. Experimental results have shown that simply verifying the static contact resistance does not guarantee reliable contact in dynamic environments. Because connectors with qualified contact resistance often experience momentary power outages during simulated environmental tests such as vibration and impact, it is recommended to conduct 100% dynamic vibration tests on some high reliability terminal blocks to assess their contact reliability.   3) Single hole separation force detection Single hole separation force refers to the separation force that causes the contact element in the inserted state to change from static to motion, and is used to characterize the contact between the pin and the socket. Experiments have shown that a single hole separation force that is too small may cause signal transients when subjected to vibration and impact loads. Checking contact reliability by measuring single hole separation force is more effective than measuring contact resistance. Upon inspection, it was found that the single hole separation force of the socket exceeded the tolerance, and the measured contact resistance was often still qualified. For this reason, in addition to developing a new generation of flexible plug-in contacts that are stable and reliable, the production plant should not use automatic plug-in force testing machines for multi-point simultaneous testing of key models. Instead, the finished product should undergo 100% point by point single hole separation force inspection to prevent signal interruption caused by individual loose sockets.   2. Prevent poor insulation 1) Insulation material inspection The quality of raw materials has a significant impact on the insulation performance of insulators. Therefore, the selection of raw materials is particularly important. We should not blindly reduce costs and lose material quality. We should choose materials from reputable large factories. We should carefully check and verify important information such as batch numbers and material certificates for each batch of incoming materials. We should also ensure traceability of material usage   2) Insulation resistance inspection of insulators At present, some production plants require assembly into finished products before testing their electrical performance. However, due to the insulation resistance of the insulator itself being unqualified, the entire batch of finished products has to be scrapped. A reasonable process should be to conduct 100% process screening on the insulation parts to ensure that the electrical performance is qualified.   3. Prevent poor fixation 1) Interchangeability check Interchangeability check is a dynamic check. It requires that the same series of matching plugs and sockets can be plugged and connected to each other, and it can be found whether there is any failure to plug, position, and lock due to the size deviation of insulators, contacts, and other parts, missing parts, or improper assembly, or even disassembly under the action of rotational force. Another function of interchangeability inspection is to detect in a timely manner whether there are metal residues that affect insulation performance through plug-in connections such as threads and clips. Therefore, 100% inspection of important wiring terminals should be carried out to avoid such major fatal failure accidents.   2) Torque resistance inspection Torque resistance inspection is a highly effective method for assessing the reliability of terminal block structures. According to the MIL-L-39012 standard of the US military, samples should be randomly tested for torque resistance in each batch to promptly identify any issues 3) Continuity testing of crimped wires During electrical installation, it is often found that some core crimping wires are not properly connected or cannot be locked after being connected, resulting in unreliable contact. The reason for the analysis is that there are burrs or dirt stuck at the screw teeth of some installation holes. Especially when using the last few installation holes of a plug socket that have already been installed by the factory, the defect was discovered and the other holes that had already been installed were crimped with wires one by one, and the plug socket was replaced. In addition, improper selection of wire diameter and crimping aperture, or errors in crimping process operation, can also cause accidents where the crimping end is not secure. For this reason, the production factory needs to conduct a through test on all installation holes of the delivered plug (socket) samples before leaving the factory, that is, using loading and unloading tools to simulate the wires with pins or sockets that are crimped into place and check whether they can be locked. According to the product technical specifications, check the pulling force of each crimped wire one by one
    Read More
  • Types of 5.08mm Pitch Pluggable PCB Terminal Blocks
    Aug 21, 2024
    Introduce you to the various types of 5.08mm pitch pluggable PCB terminal blocks that we offer. There are a total of six different types available:1. Open straight pin PCB terminal block: This type features hollow sides in the plastic housing for easy customization of PCB length requirements. The pins are straight at 180 degrees for easy insertion.2. Open right-angle pin PCB terminal block: Similar to the straight pin type, but with right-angle pins at 90 degrees for different PCB design needs.3. Closed straight pin PCB terminal block: This type features plastic housing on both sides of the pins for added stability. The pins are straight at 180 degrees.4. Closed right-angle pin PCB terminal block: Similar to the closed straight pin type, but with right-angle pins at 90 degrees for specific design requirements.5. Flanged straight pin PCB terminal block: This type features additional flanges on both sides of the closed pins, with copper nuts inside the flanges for enhanced stability during insertion and removal. The pins are straight at 180 degrees.6. Flanged right-angle pin PCB terminal block: Similar to the flanged straight pin type, but with right-angle pins at 90 degrees for specific design applications.
    Read More
  • Several ways to connect PCB terminal blocks
    Aug 20, 2024
    1. Screw connection: This method uses screw terminals to connect wires. It is important to consider the maximum and minimum wire cross-sections allowed, as well as the maximum torque for different screw sizes.2. Soldering connection: The most common soldering method is tin soldering. It is essential to ensure that a continuous metal connection is formed between the solder material and the surface being soldered. Different types of soldering connections include solder tab style, eyelet solder tab style, and arc notch solder tab style.3. Crimp connection: Crimping is a technique where metal is compressed and displaced within specified limits to connect wires to contact pairs. Good crimp connections can produce metal intermolecular flow, resulting in symmetrical deformation of the wire and contact material. This type of connection is similar to cold welding and can withstand harsh environmental conditions.4. Wrapping connection: Wrapping involves wrapping the wire directly around the angular contact pillar. The wire is wrapped, pressed, and fixed at the angular contact pillar to create a sealed contact.
    Read More
  • The main reason of high temperature when using terminal block
    Aug 20, 2024
    There are two main reasons why terminal blocks may generate high temperatures:1. Loose terminals leading to increased circuit resistance, resulting in overheating.2. Control circuit experiencing overcurrent due to reasons such as high power supply voltage or load short circuit faults.Here are some solutions to these issues:1. Check the working voltage from the secondary coil of the transformer to the distribution cabinet and then to the electrical equipment.2. Ensure proper grounding from the transformer to the distribution cabinet to prevent common faults in grounding.
    Read More
  • PCB Terminal Block Aging Causes and Testing Methods
    Aug 13, 2024
    The aging of PCB terminal connections can be caused by various factors. Firstly, environmental conditions and temperature play a significant role. High temperatures in the surrounding environment or from heat sources can cause the terminals to overheat, leading to insulation breakdown and even explosions or fires.Secondly, chemical corrosion can also contribute to the aging of terminals. Prolonged exposure to chemical or electrolytic corrosion can degrade the protective insulation layer, reducing insulation effectiveness and accelerating aging.Lastly, operating at overload for extended periods can cause terminals to overheat due to the heating effects of current flow. Excessive temperatures can speed up insulation aging, particularly in summer months.To test for terminal aging, one method involves placing five terminals horizontally on a rail, connecting them with rated cross-section wires at least 300mm long, and measuring the voltage drop across each terminal. The test should be conducted in an aging chamber with temperature limits of 20°C to 75°C and a maximum working temperature of 120°C.During the test, a rated current flows through the terminals for both heating and cooling cycles, with voltage drop measurements taken after every 24 cycles to assess aging. The entire testing process consists of 192 cycles.Prior to testing, the voltage drop should not exceed 3.2mV. Regular monitoring of voltage drop can help identify aging terminals and prevent potential failures.If you have any further questions or require assistance with terminal aging testing, please do not hesitate to contact us.
    Read More
  • When it comes to high-quality terminal blocks, there are several key factors that must be considered in order to ensure optimal performance and reliability.
    Aug 13, 2024
    First and foremost, the materials used in the terminal blocks play a crucial role in their overall quality. The insulation housing should be made of flame-retardant engineering plastic, while the conductive components should be made of copper alloy materials. This is because the plastic insulation material and the conductive components directly influence the quality of the terminal block, determining its insulation and conductivity functions.In addition, the production process of the terminal blocks is also critical. If the production process is not up to standard, the thread processing is not done properly, and the torque is not within specifications, the terminal block will lose its ability to connect wires effectively.Furthermore, the appearance of the terminal blocks is also important. A high-quality terminal block should not only meet the functional requirements, but also have a visually appealing appearance. A well-designed terminal block can make a positive impression on users and enhance the overall user experience.In conclusion, when it comes to high-quality terminal blocks, it is essential to consider the materials used, the production process, and the overall design of the product in order to ensure optimal performance and reliability.
    Read More
  • When using PCB terminal blocks for wiring applications, it is important to keep in mind the following precautions.
    Aug 11, 2024
    When using PCB terminal blocks for wiring applications, it is important to keep in mind the following precautions:1. Always ensure that the power is switched off before starting any wiring operations. Never attempt to work on the terminal blocks while they are live. If you are unsure whether the power is off, use a voltage tester to verify. Additionally, if there are sliding buttons on the terminal blocks or switches, it is advisable to replace them if they are worn out to prevent any risk of electric shock.2. When connecting to the power source, make sure to install PVC conduit for wire routing. Avoid leaving wires hanging loosely without any proper support or fixation on support brackets or busbars.3. Pay attention to the length of the wires when connecting to the switch box. It is recommended to keep the wire lengths within a suitable range and properly route them through conduits. Avoid pushing the wires directly into the switches for fixing.By following these precautions, you can ensure safe and efficient operation of the PCB terminal blocks. If you have any further questions or need assistance, please feel free to contact us.
    Read More
  • What are pluggable terminal blocks?
    Aug 07, 2024
     This terminal block is primarily comprised of a male header and a female socket, allowing for easy and secure connection of wires and cables.One of the key features of our Pluggable Terminal Block is its versatility in terms of spacing options. We offer a variety of standard spacing options, including 3.5mm, 3.81mm, 5.0mm, 5.08mm, 7.5mm, and 7.62mm. This allows for greater flexibility in designing and customizing your electrical connections.Pluggable Terminal Block is an electrical connection device specially designed for easy connection and removal of wires. They are usually made of insulating materials and have a pluggable wire connection function, which is used to safely connect wires to circuit boards or other electronic devices.   Pluggable terminal blocks have the following main features and advantages: 1. Plug-in connection: Pluggable terminal blocks allow users to easily insert and remove wires. They usually have a spring-type or screw-type wire connection mechanism, making the connection and removal process simpler and faster. In this way, when maintenance, replacement or repair is required, the wire can be easily removed and replaced without intervening in the entire circuit or equipment.   2. Flexibility and adjustability: Pluggable terminal blocks provide flexible wire connection methods. They usually have adjustable sockets or wiring screws that can be adjusted according to wire size or demand, suitable for wire connections of different specifications.   3. Maintenance and troubleshooting: Pluggable terminal blocks play an important role in the maintenance and troubleshooting process. Through plug-in connection, it is more convenient to check, replace or repair wires without disassembling a large number of circuit boards or equipment.   4. Identification and management: Pluggable terminal blocks usually have an identification area for marking the wires or circuits connected to each terminal block. This helps to identify and manage the connections of the circuits and improve the efficiency of maintenance and troubleshooting.   5. Reliability and safety: Pluggable terminal blocks provide reliable electrical connections and have good insulation properties. They ensure the stability and safety of the wires during the connection process, reducing the risk of wiring errors and circuit failures.   In short, pluggable terminal blocks provide a convenient, flexible and fast way to connect and remove wires. They are suitable for a variety of electronic devices and circuit boards, and provide convenience and reliability during maintenance, replacement and troubleshooting. Our Pluggable Terminal Block is designed to be user-friendly and durable, ensuring a reliable and long-lasting connection for your applications. The easy plug-and-play design makes installation and maintenance a breeze, saving you time and effort.Whether you are working on a large-scale industrial project or a small-scale DIY project, our Pluggable Terminal Block is the ideal solution for your wiring needs.
    Read More
  • What is a terminal on a circuit board?
    Jul 31, 2024
    On a circuit board, terminals are metal pins or sockets for electronic components or wires. They serve as connection points and provide physical and electrical connections between electronic components and circuit boards. Here are some common types of terminals on circuit boards:   1. Socket terminals: Socket terminals are usually holes or slots made of metal for inserting pins of electronic components (such as diodes, resistors, integrated circuits, etc.). Socket terminals can provide stable and reliable connections, facilitating the plugging and unplugging and replacement of components.   2. Pin terminals: Pin terminals are metal pins of the electronic components themselves, which are connected by welding or inserting into holes on the circuit board. They can be in different forms such as straight-in pins, surface-mount pins, package pins, etc., used to connect electronic components to circuit boards.   3. Stud terminals: Stud terminals are usually used to connect high-power components or wires, such as motors, power supplies, resistors, etc. They usually have a threaded structure, and the wires are clamped and an electrical connection is established by tightening the nut.   4. Spring contact terminals: Spring contact terminals use spring force to provide a tight connection. They are usually used in occasions that require frequent plugging and unplugging, such as test points or connecting external devices.   5. Blade terminals: Blade terminals are similar to socket terminals, but are usually used for high current applications. They have blade-shaped pins that can quickly connect electronic components by plugging and unplugging.  Our team has extensively tested and evaluated the Homnecks connector terminals and we are pleased to report that they have displayed excellent performance and reliability. The terminals have shown exceptional conductivity and durability, ensuring secure and stable connections on the PCB boards. Furthermore, the use of Homnecks connector terminals has proven to be incredibly efficient and user-friendly. The terminals are easy to install and provide a secure connection without the need for additional tools or complicated processes. This not only saves time during assembly but also reduces the risk of errors or malfunctions. The function of the terminal is to provide a reliable electrical connection on the circuit board, allowing electronic components to pass current and signals to and from the circuit board. They allow for assembly, maintenance and testing of circuit boards, and provide flexibility and convenience. Different types of terminals are suitable for different connection needs and are selected according to the specific application and component type.  
    Read More
  • What is PCB terminal block?
    Jul 01, 2024
    PCB terminal block refer to electrical connection devices for connecting on printed circuit boards (PCBs). They provide a reliable and convenient way to connect and disconnect circuits, and are usually used to fix wires or connect plugs, sockets and other devices.   There are many types of PCB terminals, the most common of which include:   1. Pluggable terminal block:The Pluggable PCB Terminal Blocks are available in different configurations to suit your specific needs. The main types include male parts and female parts, with standard pin spacings of 2.5mm, 3.5mm, 3.81mm, 5.0mm, 5.08mm, 7.5mm, and 7.62mm. Homnecks provide flexibility for various design requirements and compatibility with different systems.   2.Screw terminal block: a convenient and efficient solution for your PCB assembly needs. Our Screw Terminal Block can be directly soldered onto your PCB board, allowing for easy and secure wire connections. The screw terminals provide a reliable and secure connection that can easily be loosened or tightened for quick and convenient wire adjustments.   3. Barrier  terminal block: PCB Barrier Terminal Block, designed for high-performance controller products that require superior electrical properties. Featuring a plastic material made of flame-retardant PA66 and tin-plated copper metal components, our Barrier Terminal Block offers excellent electrical performance. This makes it ideal for applications where high current and voltage requirements are a priority. 4.Spring Terminal: Spring terminals use spring mechanisms to achieve circuit connection by clamping wires or terminal pins. This type of terminal usually has the characteristics of quick connection and disconnection, which is convenient for maintenance and replacement.   Our terminal blocks are manufactured with high-quality materials to ensure reliable performance and durability. They are designed for easy installation and maintenance, making them ideal for a wide range of industrial and commercial applications.
    Read More
  • What is the function of terminal block?
    Jul 06, 2024
    Terminal blocks are electrical connection devices used to safely connect wires in a circuit together or to electrical equipment. They are usually made of insulating materials and have conductive connection points for inserting or connecting wires.   Homnecks Terminal blocks have the following main functions: 1. Homnecks Terminal blocks can make wire connection: Terminal blocks provide a safe and reliable connection point for wires. Wires can be connected to terminal blocks by insertion, crimping or threading. This makes it easier to maintain and replace wires when they need to be connected or disconnected without directly affecting the entire circuit.   2. Homnecks Terminal blocks can make line distribution: Terminal blocks are often used to distribute current from one circuit to multiple branch circuits. By connecting different wires to terminal blocks, current can be divided and distributed, making circuit design more flexible and variable.   3.  Homnecks Terminal blocks can Insulation and protection: Terminal blocks are usually made of insulating materials and can provide electrical isolation and protection. This prevents problems such as short circuits and electric shocks between wires and reduces accidental risks.   4. Homnecks Terminal blocks can  Identification and management: Terminal blocks usually have identification areas to mark the wires or circuits connected to each terminal block. This helps identify and manage circuit connections and improves the efficiency of maintenance and troubleshooting. We are confident that our Homnecks Terminal Block will enhance the functionality and efficiency of your controller products. If you have any questions or would like to learn more about our product, please do not hesitate to contact us. We look forward to the opportunity to collaborate with you on your upcoming projects.
    Read More
1 2 3
A total of3pages

leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit